Observation of the expansion behavior and quantitative evaluation of elastic recoil of a balloon-expandable stent in three dimensions using a Micro-CT system

F Mori, T Nakayama, T Matsuzawa… - Technology and Health …, 2012 - content.iospress.com
Percutaneous transluminal coronary angioplasty (PTCA) with stent implantation is widely
used for the treatment of coronary stenosis. However, restenosis after stent implantation …

3D Observation of Expansion of Stent and Elastic Recoil using Micro-CT

F Mori, T Nakayama, T Matsuzawa, M Ohta - World Congress on Medical …, 2009 - Springer
The behavior of an expansion of balloon-expandable stent is in three-dimensional space.
Therefore, it is necessary to observe in three-dimensions, however little previous research …

Micro-CT–compatible technique for measuring self-expanding stent forces

HN Nikolov, DM Pelz, SP Lownie, CJD Norley… - Journal of Vascular and …, 2010 - Elsevier
PURPOSE: To develop and evaluate a technique for measuring the radial resistive force,
chronic outward force, and dimensions of self-expanding stents. MATERIALS AND …

Measurement of the symmetry of in vitro stent expansion: a stereo-photogrammetric approach

AJ Narracott, DR Hose, PV Lawford… - Journal of medical …, 2003 - Taylor & Francis
Balloon-expandable stents are used routinely in the treatment of coronary artery disease.
Their effectiveness is limited by the occurrence of restenosis. Previous studies have …

X-ray micro-tomography of a coronary stent deployed in a model artery

T Connolley, D Nash, JY Buffière, F Sharif… - Medical engineering & …, 2007 - Elsevier
Coronary stents are small scaffolds routinely implanted during angioplasty procedures to re-
open coronary arteries which have become narrowed by an atherosclerotic plaque. Despite …

Balloon folding affects the symmetry of stent deployment: experimental and computational evidence

AJ Narracott, PV Lawford, JPG Gunn… - 2007 29th Annual …, 2007 - ieeexplore.ieee.org
The level of restenosis following coronary artery stenting may be related to the deployed
stent geometry. This study investigated the influence of two balloon folding patterns …

TCTAP A-094 Assessment of Differences in Degree of Elongation Between Stents by Coronary CT Angiography

H Yoshida, A Matsumura - Journal of the American College of Cardiology, 2014 - jacc.org
Background Stent elongation during percutaneous coronary intervention (PCI) has been
recently reported. At our hospital, bench test using phantom confirmed different degree of …

Finite element analysis of the expansion behavior of coronary stents

W Wang, D Yang, M Qi - Sheng wu yi xue Gong Cheng xue za zhi …, 2006 - europepmc.org
Coronary stent is an important device used in Percutaneous Transluminal Coronary
Angioplasty (PTCA) which is usually implanted to support the stenosed artery. Its expansion …

TCT-540 Longitudinal Drug Eluting Stent Elongation Phenomenon due to high pressure additional dilatation; Insights from bench testing

T Domei, K Amemiya, T Ito, M Iwabuchi - Journal of the American College of …, 2012 - jacc.org
Background Recently, stent longitudinal deformation is becoming to be one of the clinical
issue. The objective of this study was to evaluate how post stent dilatation with large balloon …

3D Stent Reconstruction Using CMCT: A Novel Method to Assess Stent Expansion

HA Haidar, M Perier, H Benamer - Case Reports, 2024 - jacc.org
Stent underexpansion in calcified coronary stenosis is an important predictor of major short-
and long-term adverse cardiovascular events. In this case, we describe a novel method for …